Hardware concept

The sensor unit

A plan and a drawn mock-up for the device that sits at a water point. It has not been built or tested.

The mock-up

One unit at each pump, tank or tap. It reads the water, sends the readings over the mobile network, and shows the water point's status to people who have no phone.

123456789

From the outside

  1. Solar panel. Charges the battery inside the case. Its size has not been worked out yet.
  2. Status sign. Three lamps show the water point's status as the service holds it: Safe, Caution or Unsafe. Each lamp has its own shape as well as its own colour. If the unit has not heard from the service for a day, the lamps go out. No lamp lit means the status is not known. It does not mean Safe.
  3. Sealed case. Holds the electronics, the battery and the SIM card behind a locked service door. Readings are kept inside when there is no signal and sent when it returns.
  4. Measuring cell. A dark chamber the water runs through. The cloudiness reading is taken here, and only while a flow switch senses water moving.
  5. Water in. A small side line from the pump spout, the tap or the tank outlet.
  6. Water out. Runs to the drain. Water that has been through the unit is not returned to the supply.
  7. Point label. The name and code of the water point, so a report or an alert refers to the right place.
  8. Bracket. Fixes the unit to the pump stand or a wall with bolts that need a special tool.
  9. Chlorine add-on. Fitted on chlorinated supplies only, such as taps and tanks. It holds a chlorine probe and a pH probe.
90°12345

Inside the measuring cell

  1. Infrared light. A small infrared LED (860 nm) shines across the water.
  2. Detector at 90°. Measures the light that particles scatter sideways. Cloudier water scatters more. This is the cloudiness reading.
  3. Reference detector. Measures the light that gets straight through. Comparing the two detectors is a known way to steady the reading. Whether it copes with dirty windows here has to be tested.
  4. Matt black walls. Stop stray light reaching the detectors.
  5. Temperature probe. The LED's brightness changes with temperature, so the reading is corrected for it.

The drawings and the layout of the unit are original to this concept. The way it measures is standard, and the cloudiness cell follows an open-source design by Kelley and others (2014) (opens in a new tab).

What it reads, and what it does not

Every unit reads cloudiness and temperature. Chlorine and pH need the add-on and a chlorinated supply.

Cloudiness (turbidity)

Fitted to
Every unit
How
Infrared light scattered at 90°, the arrangement used in the ISO 7027 standard.
Why
The guideline is below 5 NTU, ideally below 1. A sudden rise is a warning sign.

Free chlorine

Fitted to
The add-on, on chlorinated supplies only
How
An electrochemical probe behind a membrane.
Why
At least 0.2 mg/l should be left at the tap. A fall shows that dosing has stopped.

pH

Fitted to
With the chlorine add-on
How
A pH probe beside the chlorine probe.
Why
The chlorine reading depends on pH and has to be corrected for it.

Water temperature

Fitted to
Every unit
How
A small probe in the measuring cell.
Why
Used to correct the cloudiness reading.
Not read: GermsNo part of this unit detects E. coli or any other germ. A monitor's kit test does that.
Not read: ArsenicArsenic and other chemicals are not measured. Each borehole, well and spring gets a kit test.

The 90° arrangement is described in this guide to turbidity methods (opens in a new tab), and the need to correct chlorine for pH in this note on chlorine probes (opens in a new tab). The ISO standard itself was not read for this page.

What is already known

Two parts of the unit have been shown to work by others. One part is harder than the drawing makes it look.

The cloudiness sensor has been built for under $25 in parts

Kelley and others (2014) built an open-source meter from an 860 nm LED and a light sensor set at 90°. It ran hourly for three months on four AA batteries and came close to a commercial meter from 0 to 1,000 NTU.

That was a handheld meter reading a sample in a small tube, at 2014 prices. The authors list a rugged, in-line version as work still to do.

Source: Kelley and others: an affordable open-source turbidimeter (opens in a new tab)

Sending readings by text message has been done

The same team added a mobile modem to their meter and exchanged text messages with a server in both directions. Treatment plants in Honduras were reporting readings twice a day in the same text format.

The modem added $40 to $100 to the parts cost in 2014.

Source: Kelley and others, section 3.3 (opens in a new tab)

The chlorine sensor is the hard part

One manufacturer's instructions for a membrane chlorine probe ask for a steady flow of at least 0.75 litres a minute past the probe, a 12 to 24 volt supply, a check against a colour test kit every week to month, and new filling solution about every two months.

At that flow the sample comes to about 1,080 litres a day if it runs to waste. Other kinds of probe may need less. This is one example, not a recommendation.

Source: Sensorex: instructions for a free chlorine probe (opens in a new tab)

The plan

Five stages, cheapest and surest first. Each stage ends with a test, and the next one starts only when that test is passed.

  1. Bench

    Build the cloudiness cell on a bench

    Reproduce the published design and add the reference detector. Check it against a reference meter using standard cloudy liquids.

    Done when
    It can tell 1 NTU from 5 NTU reliably. Those are the two values the guideline uses.
  2. Flowing water

    Make it read water as it flows

    Fit the cell on a side line with a flow switch. Run it for weeks to see what air bubbles and dirt on the windows do to the reading.

    Done when
    The reading stays true for a month without cleaning, or it is known how often the windows need cleaning.
  3. Chlorine

    Choose a chlorine method, or leave chlorine out

    Compare kinds of chlorine probe for the water they use, the power they need and the upkeep they ask of the operator.

    Done when
    One probe fits a water, power and upkeep budget the operator accepts. If none does, chlorine stays a test the monitor does by hand.
  4. Field unit

    Add the case, the power, the sign and the radio

    Build the sealed case. Size the solar panel and battery from measured power use. Add the status sign and the store of unsent readings.

    Done when
    A unit runs outdoors for a month with no one attending it, through days without sun and days without signal.
  5. Pilot

    Fit a few water points and compare with the monitor's tests

    Fit units at a few water points of different kinds. Compare their readings with the monitor's checks, and ask people at the pump what the sign tells them.

    Done when
    The water committee, the operator and the health authority have seen the results and agreed whether to go further.

No time or cost is given for these stages. Both need an estimate from an engineer who has built water sensors.

Not known yet

Six things this concept does not answer.

What a unit costs

Only the cloudiness parts have a published price. The case, the power, the radio and the chlorine add-on have not been costed.

Fitting it to a handpump

Water only flows when someone pumps. How to take a side stream from a spout without letting dirt in has not been solved.

Dirty windows

Slime and scale build up on the optics. Whether the monitor wipes them on each round or the unit cleans itself is not decided.

Whether people read the sign correctly

The three lamps and the rule that no light means not known have to be tested with people who use the pump.

Materials and approval

Every part that touches drinking water has to be approved for it. What a national authority requires of the unit and its radio has not been looked into.

Theft, damage and patents

A solar panel and a battery are worth stealing. The design has also not been checked against existing patents.