Cloudiness (turbidity)
- Fitted to
- Every unit
- How
- Infrared light scattered at 90°, the arrangement used in the ISO 7027 standard.
- Why
- The guideline is below 5 NTU, ideally below 1. A sudden rise is a warning sign.

Hardware concept
A plan and a drawn mock-up for the device that sits at a water point. It has not been built or tested.
One unit at each pump, tank or tap. It reads the water, sends the readings over the mobile network, and shows the water point's status to people who have no phone.
The drawings and the layout of the unit are original to this concept. The way it measures is standard, and the cloudiness cell follows an open-source design by Kelley and others (2014) (opens in a new tab).
Every unit reads cloudiness and temperature. Chlorine and pH need the add-on and a chlorinated supply.
The 90° arrangement is described in this guide to turbidity methods (opens in a new tab), and the need to correct chlorine for pH in this note on chlorine probes (opens in a new tab). The ISO standard itself was not read for this page.
Two parts of the unit have been shown to work by others. One part is harder than the drawing makes it look.
Kelley and others (2014) built an open-source meter from an 860 nm LED and a light sensor set at 90°. It ran hourly for three months on four AA batteries and came close to a commercial meter from 0 to 1,000 NTU.
That was a handheld meter reading a sample in a small tube, at 2014 prices. The authors list a rugged, in-line version as work still to do.
Source: Kelley and others: an affordable open-source turbidimeter (opens in a new tab)
The same team added a mobile modem to their meter and exchanged text messages with a server in both directions. Treatment plants in Honduras were reporting readings twice a day in the same text format.
The modem added $40 to $100 to the parts cost in 2014.
One manufacturer's instructions for a membrane chlorine probe ask for a steady flow of at least 0.75 litres a minute past the probe, a 12 to 24 volt supply, a check against a colour test kit every week to month, and new filling solution about every two months.
At that flow the sample comes to about 1,080 litres a day if it runs to waste. Other kinds of probe may need less. This is one example, not a recommendation.
Source: Sensorex: instructions for a free chlorine probe (opens in a new tab)
Five stages, cheapest and surest first. Each stage ends with a test, and the next one starts only when that test is passed.
Bench
Reproduce the published design and add the reference detector. Check it against a reference meter using standard cloudy liquids.
Flowing water
Fit the cell on a side line with a flow switch. Run it for weeks to see what air bubbles and dirt on the windows do to the reading.
Chlorine
Compare kinds of chlorine probe for the water they use, the power they need and the upkeep they ask of the operator.
Field unit
Build the sealed case. Size the solar panel and battery from measured power use. Add the status sign and the store of unsent readings.
Pilot
Fit units at a few water points of different kinds. Compare their readings with the monitor's checks, and ask people at the pump what the sign tells them.
No time or cost is given for these stages. Both need an estimate from an engineer who has built water sensors.
Six things this concept does not answer.
Only the cloudiness parts have a published price. The case, the power, the radio and the chlorine add-on have not been costed.
Water only flows when someone pumps. How to take a side stream from a spout without letting dirt in has not been solved.
Slime and scale build up on the optics. Whether the monitor wipes them on each round or the unit cleans itself is not decided.
The three lamps and the rule that no light means not known have to be tested with people who use the pump.
Every part that touches drinking water has to be approved for it. What a national authority requires of the unit and its radio has not been looked into.
A solar panel and a battery are worth stealing. The design has also not been checked against existing patents.